Setfipparams – Dell Emulex Family of Adapters User Manual

Page 1380

Advertising
background image

OCM for VMware vCenter Version 10.2 User Manual

P009805-01A Rev. A

11. Using OneCommand Manager for VMware vCenter Command Line Interface

The Command Reference

1380

Example:

elxvcpcmd v=12.345.678.901 u=username p=password h=12.345.678.123

setdumpdirectory 10:00:00:00:c9:61:f2:64 vcenter-datastore

This example shows the dump directory set to /vmfs/volumes/vcenter-datastore.

setfipparams

Syntax

elxvcpcmd.exe v=<vcenter_server> u=<vc_username> p=<vc_password>

h=<esx_host> setfipparams <WWPN> <Param> <Value>

Description

This command sets the FIP parameters of the adapter in FCoE mode.

Parameters

Example:

elxvcpcmd v=12.345.678.901 u=username p=password h=12.345.678.123

setfipparams 10:00:00:00:c9:5b:3a:6d fcmap 0x0efc99

setexpresslanelunstate (LPe16000–Series and OCe15100–
Series Only)

Syntax

setexpresslanelunstate <WWPN> <Target WWPN> <Lun> <State> <Option>

Description

This command enables and disables ExpressLane on a particular LUN.

v

The vCenter server IP address.

u

The user name for the vCenter server.

p

The user password for the vCenter server.

h

The IP address of the ESXi host with Emulex adapters.

WWPN

The WWPN of a port on the ESXi host with Emulex adapters.

Param

FIP parameter name (pfabric, pswitch, vlanid, fcmap and cinvlanid).

Value

FIP parameter value and the valid range for the FIP parameter.

pfabric – 8 byte fabric name (format XX:XX:XX:XX:XX:XX:XX:XX)

pswitch – 8 byte switch name (format

XX:XX:XX:XX:XX:XX:XX:XX)

vlanid – 2 byte VLAN ID [0-4095] OR 'any' for any valid VLANID

fcmap – 3-byte FC_map, 0x0EFCxx

cinvlanid – 2-byte VLAN_ID [0-4095]

Advertising