700

Viewing the FC/FCoE Event Log

Event Log Interpretation

All events logged by Emulex Storport Miniport are in Event ID 11 with source

“elxfc/elxcna”.

The Storport Miniport driver parameter LogErrors determines what type of

events are logged by the driver; the default setting is “3” which logs only events

of a SEVERE nature; the optional setting of “2” logs events of both SEVERE and

MALFUNCTION type; the optional setting of “1” logs events of SEVERE,

MALFUNCTION and COMMAND type.

Note: For troubleshooting SAN connectivity or device discovery issues, set the

LogErrors to 1.

The Emulex event code is found in byte 0010 and supplementary data is in byte

offsets 0011 through 0013.

Additional Event Log Information

The following tables are not comprehensive but do include those codes, which through

Emulex's experiences in our support and testing environments, we feel are most likely

to show up in SAN environments where issues occur.

ELS/FCP Command Error Status Codes

Internal firmware codes posted by the adapter firmware that explain why a particular

ELS or FCP command failed at the FC level.

CT Command Response Codes

Codes that indicate the response to a FC Common Transport protocol command.

Table A-5 ELS/FCP Command Error Status Codes

Explanation

Code

Remote Stop – Remote port sent an ABTS

0x2

Local Reject – Local Reject error detail

0x3

LS_RJT Received – Remote port sent LS_RJT

0x9

A_RJT Received – Remote port sent BA_RJT

0xA

Table A-6 CT Command Response Codes

Explanation

Code

FC Common Transport Reject

0x8001

FC Common Transport Accept

0x8002