8. Managing Adapters and Ports

FC/FCoE

159

2. Select the DCB tab.

Figure 8-32 DCB Tab (FCoE Adapter Port Selected)

DCB Tab Field Definitions

DCBX State – The current DCBX state (enabled or disabled).

LLDP Transmit State – DCBX uses LLDP to exchange parameters between two

link peers. For the DCBX protocol to operate correctly, both LLDP Rx and Tx

must be enabled. If either Rx or Tx is disabled, DCBX is disabled.

LLDP Receive State – DCBX uses LLDP to exchange parameters between two

link peers. For the DCBX protocol to operate correctly, both LLDP Rx and Tx

must be enabled. If either Rx or Tx is disabled, DCBX is disabled.

PFC Properties Area

State – Enabled means that flow control in both directions (Tx and Rx) is

enabled. Disabled means that priority-flow control is currently disabled. The

priority value, if Shown, is not applicable. This may be caused by:

The switch port priority-flow control being set to On instead of Auto

Switch port using port flow control instead of priority flow control

PFC disabled at adapter or switch

Active Priorities – Lists the priorities with PFC set to enabled.

Sync’d – If yes, the PFC priorities have been set by the peer. This parameter

cannot be set.

Error – The error state. This capability indicates whether an error has occurred

during the configuration exchange with the peer. Error is also set to YES when

the Compatible method for the capability fails.