0582: Error <rc> during sgl post operation
The SGL post operation failed.
Data:
None
Severity: Error
Log:
LOG_MBOX, LOG_IP verbose
Action:
None required.
0602: Failed to allocate CQ_EVENT entry
Failed to allocate a CQ_EVENT entry.
Data:
None
Severity: Error
Log:
LOG_SLI
Action:
None required.
0603: Invalid work queue CQE subtype (x%x)\n", cq-<subtype>
Invalid work queue CQE.
Data:
None
Severity: Error
Log:
LOG_SLI
Action:
None required.
0700: Bus Reset on target <i> failed
The bus reset for the specified target failed.
Data:
None
Severity: Error
Log:
LOG_FCP
Action:
None required.
0704: At limitation of <total> preallocated command buffers
The maximum number of command buffers have already been allocated.
Data:
None
Severity: Warning
Log:
LOG_FCP verbose
Action:
None required.
0705: Allocation request of <num> command buffers will exceed max of
<hba_queue_depth>. Reducing allocation request to <size>
The number of command buffers requested will exceed the maximum so a smaller quantity will be
allocated.
Data:
None
Severity: Warning
Log:
LOG_FCP verbose
Action:
None required.
0708: Allocation request of <num_to_alloc> command buffers did not succeed.
Allocated <num_allocated> buffers.
The allocation request for the specified command buffers did not succeed. However, the specified
number of buffers has been allocated.
Data:
None
Severity: Warning
Log:
LOG_FCP
Action:
None required.
Table 4-4 LPFC Error Log Messages and their Descriptions (Continued)