Appendix A. Error and Event Log Information

NIC Error and Event Logs

704

NIC Error and Event Logs

Viewing the NIC Error Log

For Windows Server operating systems, the network driver generates error codes in the

system event log. These error codes can be viewed by using the Event Viewer

application.
To view the error codes:
1. Click the Start tab on the bottom of the screen.
2. Click Run.
3. Type eventvwr and click OK.
4. Click Windows Log.
5. Click System.
6. Click the be2net error under System Events to show the event details.

RoCE Event Log

The Windows Device Manager generates error log codes if any errors occur during the

installation of the NIC/RoCE driver. Each log contains a Message Id, Severity, and

Symbolic Link. The Message Id is unique and tracks the error message if it is not

displayed.
Table A-12 shows the list of error codes, the severity of the error, the message

displayed, the meaning of the error, and recommended resolutions. When reporting an

issue with the adapter to Emulex, check the event log and report any of these entries

that may be present.

Table A-12 RoCE Event Log Entries

Message ID
Hexadecimal/
Decimal

Severity

Message

Recommended Resolution

0x3F/63

Warning

<adapter>: Incorrect RoCE
profile selected, select the
RoCE-2 profile.

Select the RoCE-2 profile.

0x3C/60

Warning

The adapter ran out of
resources while creating the
requested number of SMB
Direct connections. Please
reduce the connection count
to a supported value.

Reduce the connection count to a
supported value.

0x3B/59

Warning

RoCE is not enabled. Update
the firmware and ensure that
the RoCE-2 profile is
selected.

Update the firmware and ensure that
the RoCE-2 profile is selected in the
OneCommand Manager application, the
OneCommand Manager CLI, or the PXE
Boot utility.