Dell Emulex Family of Adapters User Manual

Page 931

Advertising
background image

Emulex Drivers Version 10.2 for Linux User Manual

P010081-01A Rev. A

4. Troubleshooting

Log Messages

931

1310: Menlo Maint Mode Link up Event <eventTag> rcvd

The link is up in maintenance mode; only management commands are allowed.

Data:

(1) fc_eventTag (2) port_state (3) vport fc_flag

Severity: Error
Log:

LOG_LINK_EVENT

Action:

None required.

1312: Link Down Event <eventTag> received

Maintenance mode link up notification received without entering link down.

Data:

(1) fc_eventTag (2) port_state (3) vport fc_flag

Severity: Error
Log:

LOG_LINK_EVENT

Action:

None required.

1400: Failed to initialize sgl list.

Failed to initialize SGL list during initialization.

Data:

None

Severity: Error
Log:

LOG_INIT

Action:

None required.

1401: Failed to enable pci device.

Failed to enable PCI device during initialization.

Data:

None

Severity: Error
Log:

LOG_INIT

Action:

None required.

1402: Failed to set up pci memory space.

PCI initialization failed.

Data:

None

Severity: Error
Log:

LOG_INIT

Action:

None required.

1403: Failed to set up driver resource.

Driver resource initialization failed.

Data:

None

Severity: Error
Log:

LOG_INIT

Action:

None required.

1404: Failed to set up driver resource.

Driver resource initialization failed.

Data:

None

Severity: Error
Log:

LOG_INIT

Action:

None required.

Table 4-4 LPFC Error Log Messages and their Descriptions (Continued)

Advertising