elx_mes0345: Resetting board due to mailbox timeout

DESCRIPTION: A mailbox command failed to complete. The driver is resetting the

port.
DATA: None
ACTION: If the mailbox command fails again, set the lpfc_log_verbose to LOG_MBOX

and retry.

elx_mes0346: Ring <ring number> handler: unexpected ASYNC_STATUS
evt_code <evtcode>

DESCRIPTION: The adapter received an asynchronous event that was not a

temperature event.
DATA: None
ACTION: None required.

elx_mes0347: Adapter is very hot, please take corrective action.
Temperature: <value> Celsius

DESCRIPTION: Adapter temperature is above normal range
DATA: Temperature in Celsius
ACTION: Shutdown and remove the adapter. Contact customer support.

elx_mes0348: NameServer login: node freed

DESCRIPTION: The enable mode failed to free up the nameserver login.
DATA: None
ACTION: None required.

elx_mes0349: rc should be MBX_SUCCESS

DESCRIPTION: The next mailbox command on the mailbox queue has failed.
DATA: None
ACTION: None required.

elx_mes0350: rc should have been MBX_BUSY

DESCRIPTION: Attempting to unregister a default RPI from an interrupt context and

the mailbox state is not busy.
DATA: None
ACTION: None required.