Control panels – Grass Valley NV9000-SE v.3.0 User Manual

Page 287

Advertising
background image

NV9000-SE Utilities • User’s Guide

267

11. Control Panels

Adding a Control Panel

4 In the ‘Button Layout’ section, select a blank button and then in the ‘Button Definitions’ sec-

tion, select a definition for the button from the drop-down list. The button definition appears on
the selected button in the ‘Button Layout’ section. Buttons in the left-hand section (32 total)
may only be assigned Destination, Level, Salvo, Source and Undefined. The buttons that appear
in the right-hand section (6 total), may be assigned any of the functions listed below.
There are two classes of buttons:

• Those that assign a dedicated function to a button directly, such as ‘Def State’ (default state)

or ‘Clear’.

• Those that define a variable function, such as ‘Destination’. Additional options display

enabling you to define the variables.

Select from the following button options:

5 In the ‘Outputs’ and ‘Inputs’ sections, define the general-purpose I/O (GPIO) connections at the

rear of the control panel as described in

Defining General Purpose I/O (GPIO) Connections

on

page 337.

Button

Modes

Description

Related Topic

Destination

XY only

Selects a destination device. Choose a

destination from the drop-down list. An
optional ‘Level Set Filter’ may be selected
to limit the devices that display to only

those in the selected level sets.

Level Sets

on page

111

Level

XY, MD

Shows the status of a specific level on the
display. When a level button is assigned, a

‘Virtual Level’ drop-down menu appears.
Choose one of the levels or ‘none’.

Level Sets

on page

111

Name Set Toggle All modes

Toggles between the default name set and

the system name set.

Name Set Toggle

on

page 363

Panel Lock

XY, MD

Prevents accidental changes to the control
panel settings. When the control panel is

locked, the button array becomes blank
except for the Panel Lock button.

Panel Lock

on page

363

Salvo

XY, MD

Places the control panel in ‘Salvo’ mode.

The button is required if you want access to
system salvos.
When you assign ‘Salvo’ to a button, a

drop-down list appears in which you select
a salvo ID.

Salvos

on page 364

and

Salvos

on page 431

Source

XY, MD

Loads a predefined source device into the

preset column, ready for selection by
pressing Take.
When you assign ‘Source’ to a button, a

drop-down list appears in which you select
a source(s). Select a level from ‘Level Set
Filter’ to limit the sources to only those

assigned to that level. (The same is true if
selecting destinations in multi-destination
mode.)

Source

on page 365

Undefined

XY, MD

Makes the button undefined and inactive. It
will remain unlit.

Advertising