Adding system parameters, How to add a system parameter, 7 click save – Grass Valley NV9000-SE v.3.0 User Manual
Page 69: Viewing system parameters, System management

NV9000-SE Utilities • User’s Guide
49
5. System Management
Managing System Parameters
Adding System Parameters
Using the ‘SysParams’ table, new system parameters can be added at any time. NV9000-SE saves
all configuration changes to the database. Once changes are saved, there is no “undo” function; the
configuration is permanently altered. To implement saved configuration changes, the changes must
be written to the system controller for dispersal to connected routers. For information on imple-
menting changes, see
Implementing Configuration Changes
How to Add a System Parameter
1 Launch NV9000-SE. (See
Launching and Exiting the Application
2 From the Navigation area, select the ‘Views’ pane, then ‘SysParams’. The ‘SysParams’ table
appears:
Figure 5-8. SysParams Table
3 Click
Add
. A blank row appears at the bottom of the table.
4 In the blank row, enter a ‘Name’ for the parameter in the field provided.
5 In the same row, enter a ‘Value’ in the field provided.
6 (Optional) Enter a ‘Description’ of the parameter in the field provided.
7 Click
Save
.
8 Click
X
on the window title tab to close the table.
Viewing System Parameters
System parameters are viewed using the ‘SysParams’ table, accessed through the ‘Views’ pane. By
default, the parameter PANEL_PRESET_TIMEOUT appears. The parameter set the time-out delay
in seconds for preset blanking on NV9601 panels when using semiautomatic data routing.