Home Parameters

Homing refers to the process of orienting a linear or rotary axis to a
specific, repeatable, mechanical position. This chapter covers the AMP

parameters that the control uses to home the axes.

If you have configured your axis as open loop, servo off, or servo

detached, you do not need to set the parameters in this chapter. Refer to

Chapters 7 and 8 for more information on Digital or Analog Servo

Parameters.

Access these parameters by selecting the “Home Parameters” group on the

AMP main menu screen.

Proj:

AMPTEST

Appl:

AMP

Util:

Edit

F2-Project F3-Application F4-Utility

F5-Configuration

F1-File

F2-Axis

F3-Options

F4-Quick Edit!

F5-Process

Type : Lathe

AXIS: X <P1> - linear

P1:

File : TEST

-

Home

Parameters

-

Dir. to Move Off Limit Switch (1)

: negative direction off switch

Home Calibration (1)

: 0.00000 mm

Axis Position after Homing (1)

: 0.00000 mm

Home Speed from Limit Switch (1)

: 254.0004 mmpm

G28 Direction to Home (1)

: plus

G28 Home Speed (1)

: 254.0000 mmpm

G30 Secondary Home Position (1)

: 0.00000 mm

G30 3rd Home Position (1)

: 0.00000 mm

G30 4th Home Position (1)

: 0.00000 mm

Machine Pos. at DCM Scale 0 (1)

: 0.00000 mm

An axis can be homed manually or automatically (G28) as described in

your programming and operation manuals. The basic homing process is

described later in this chapter: