4 home calibration – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 113

Advertising
background image

Home Parameters

Chapter 5

5-11

Notes

This parameter must be set independently for each axis.

This parameter is not used for axes that use distance coded marker linear

feedback devices.

Function

This parameter specifies the distance from the encoder marker to the

desired home position. The control moves this distance plus the distance

to the encoder marker after the home limit switch changes from “ON”

to “OFF.”

Use this parameter to define a precise mechanical home position without

adjusting the home limit switch or encoder positions.

Axis

Parameter

Number

Axis

Parameter

Number

(1)

[1300]

(7)

[7300]

(2)

[2300]

(8)

[8300]

(3)

[3300]

(9)

[9300]

(4)

[4300]

(10)

[10300]

(5)

[5300]

(11)

[11300]

(6)

[6300]

(12)

[12300]

Range

--999999.99000 to 999999.99000 mm

or

--39370.07835 to 39370.07835 in.

Notes

Use this parameter to compensate for mechanical changes that otherwise

would have relocated the home position for an axis.

For example, it may be necessary to move the encoder or home limit

switch to avoid the undesirable condition mentioned in the Caution note on

page 5-7. Use the Home Calibration parameter to compensate for this

mechanical change.

5.1.4

Home Calibration

Advertising