Servo Parameters

Chapter 7

7-83

Function

Feed to hard stop is only available on mill control types.

Use this parameter to have the servo for an axis that has reached a hard

stop maintain a holding torque to keep constant pressure against the hard

stop. If all motor torque was removed from an axis that has reached a hard

stop some bounce could occur allowing the axis to move away from the

mechanical stop. Also once a motor reaches the hard stop it would be

impossible for the servo to respond quick enough, without a holding

torque, to prevent any instantaneous forces from momentarily forcing the

axis away from the hard stop.

This parameter specifies the torque that the servo generates to maintain

force against a hard stop once it has been reached. Enter this torque value

as a percentage of the servo’s maximum rated torque.

Axis

Number

Axis

Number

(1)

[1150]

(7)

[7150]

(2)

[2150]

(8)

[8150]

(3)

[3150]

(9)

[9150]

(4)

[4150]

(10)

[4150]

(5)

[5150]

(11)

[5150]

(6)

[6150]

(12)

[6150]

Range

1 to 100% of motor rated current (continuous duty)

Notes

In order to perform feed to hard stop you must set the Servo Loop Type

parameter as either position/velocity or digital.

This parameter must be set independently for each axis that uses the feed to

hard stop feature.

7.3.16

Hard Stop Holding Torque