Tuning AMP at the Machine
Chapter 40
40-24
Important: Only axis calibration parameters can be backed up from a
storage device.
If the axis calibration parameters are being copied from a backup of the
axis calibration parameters stored on a storage device:
1.
Press the
{FROM PORT A}
or
{FROM PORT B}
softkey, depending on
which port the peripheral device is connected to.
This screen is displayed on the operator panel CRT:
ACTIVE COPY PARAMETERS
FROM:
PORT A (or PORT B)
TO:
AXIS CALIBRATION
DEVICE:
ALLEN-BRADLEY 1770-SB
BAUD RATE:
9600
PARITY:
NONE
STOP BITS:
1
DATA LENGTH:
8
YES
NO
If you want:
Press this softkey:
the control to backup the axis calibration
parameters from the peripheral device
{YES}
the backup procedure to abort
{NO}
END OF CHAPTER