background image

Feedrate Parameters

Chapter 9

9-2

Standard motion feedrate parameters include:

Parameter:

Page:

Rapid Feedrate For Positioning

9-2

Maximum Cutting Feedrate

9-3

Function

Use this parameter to determine the feedrate that is used by the control for

rapid positioning. This mainly includes the feedrate of axis motions when

in the G00 mode; however, this feedrate is used for other operations as

specified in your programming and operation manual.

Axis

Parameter

Number

Axis

Parameter

Number

(1)

[1203]

(7)

[7203]

(2)

[2203]

(8)

[8203]

(3)

[3203]

(9)

[9203]

(4)

[4203]

(10)

[10203]

(5)

[5203]

(11)

[11203]

(6)

[6203]

(12)

[12203]

Range

0.00000 to 243840.00000 mmpm
or
0.00000 to 9600.00000 ipm

Notes

This feedrate may be modified by the operator with the rapid feedrate

override switch.

A value for this feedrate is set independently for each axis. Motions that

use more than one axis for rapid positioning (including a virtual axis which

requires two axes to position) use a feedrate that will not exceed the rapid

feedrate for any of the moving axes. Refer to your operation and

programming manual for additional information.

9.1

Standard Motion Feedrate

Parameters

9.1.1

Rapid Feedrate for

Positioning

Advertising