Feedrate Parameters
Chapter 9
9-2
Standard motion feedrate parameters include:
Parameter:
Page:
Rapid Feedrate For Positioning
9-2
Maximum Cutting Feedrate
9-3
Function
Use this parameter to determine the feedrate that is used by the control for
rapid positioning. This mainly includes the feedrate of axis motions when
in the G00 mode; however, this feedrate is used for other operations as
specified in your programming and operation manual.
Axis
Parameter
Number
Axis
Parameter
Number
(1)
[1203]
(7)
[7203]
(2)
[2203]
(8)
[8203]
(3)
[3203]
(9)
[9203]
(4)
[4203]
(10)
[10203]
(5)
[5203]
(11)
[11203]
(6)
[6203]
(12)
[12203]
Range
0.00000 to 243840.00000 mmpm
or
0.00000 to 9600.00000 ipm
Notes
This feedrate may be modified by the operator with the rapid feedrate
override switch.
A value for this feedrate is set independently for each axis. Motions that
use more than one axis for rapid positioning (including a virtual axis which
requires two axes to position) use a feedrate that will not exceed the rapid
feedrate for any of the moving axes. Refer to your operation and
programming manual for additional information.