Spindle 1 Parameters

Chapter 12

12-11

For example, if it takes 20 msec for a small change in spindle speed (such

as from 0 to 5 rpm) and 160 msec for the maximum change in spindle

speed (such as from 0 to 4000 rpm), a good value to enter here would be

the average transition time, 90 msec.

Refer to the discussion for the parameter Spindle Deviation Tolerance.

If spindle DAC output ramping is on:

This parameter specifies:

the spindle acceleration /declaration time to be used by the control for
simulated feedback. Simulated feedback is explained with the

parameter Spindle Deviation Tolerance. If you have the solid tapping

feature option, enter a value for this parameter that closely matches the

spindle acc/dec curve established by the solid tapping parameters (see

page 12-4).

if your system does not have the solid tapping feature this parameter
specifies the duration of the spindle ramp (see page 12-4). This is also

the same value the control uses for simulated feedback.

Spindle

Parameter

Number

1

[70]

Range

20 to 400 msec

Notes

Simulated feedback allows the control to perform “feed per revolution”

moves on machines that do not have position feedback from the spindle.

If the spindle has position feedback and the software option for spindle

speed deviation detection has been installed, simulated feedback is also

used for spindle speed deviation detection.

This parameter must be set for each spindle axis.