Using AMP Applications and ODS Utilities

Chapter 2

2-28

The workstation displays this screen:

Proj:

TEST

Appl:

Upload

Util: Get AMP params

F2-Project F3-Application F4-Utility

F5-Configuration

F1-File

WARNING

Parameter Out of Range

Continue Checking

(C)

Edit Parameter

(E)

Quit Checking

(Q)

Correct the out of range error(s) so that the recover control image process

can be completed. If you do not correct the errors, the upload process

aborts.

If you select the:

the workstation:

and:

Continue Checking option

checks additional

parameters for out of

range errors

· if there are any others errors, the

workstation displays the previous screen

in response to each additional error

· if there are no other errors, the

workstation displays the previous screen

in response to the first error

Edit Parameter option

displays a screen listing

the legal range options for

the current parameter

Select one of the legal range options to

eliminate the out of range error, which

enables the workstation to continue

recovering the control image.

Quit Checking option

aborts the recover control

image process

· the upload process aborts
· the workstation returns to the main

menu line of ODS