The workstation displays this screen – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual
Page 54

Using AMP Applications and ODS Utilities
Chapter 2
2-28
The workstation displays this screen:
Proj:
TEST
Appl:
Upload
Util: Get AMP params
F2-Project F3-Application F4-Utility
F5-Configuration
F1-File
WARNING
Parameter Out of Range
Continue Checking
(C)
Edit Parameter
(E)
Quit Checking
(Q)
Correct the out of range error(s) so that the recover control image process
can be completed. If you do not correct the errors, the upload process
aborts.
If you select the:
the workstation:
and:
Continue Checking option
checks additional
parameters for out of
range errors
· if there are any others errors, the
workstation displays the previous screen
in response to each additional error
· if there are no other errors, the
workstation displays the previous screen
in response to the first error
Edit Parameter option
displays a screen listing
the legal range options for
the current parameter
Select one of the legal range options to
eliminate the out of range error, which
enables the workstation to continue
recovering the control image.
Quit Checking option
aborts the recover control
image process
· the upload process aborts
· the workstation returns to the main
menu line of ODS