Acc/Dec Parameters

Chapter 10

10-3

Important: If the selected position loop type is Zero Following Error, you

must use the Rapid Traverse instead of Maximum Contouring Speed.
This calculation results in a ramp expressed in inches per minute per

millisecond. Apply the appropriate conversion factors to convert it into the

units you have selected to enter via AMP. This ramp results in a linear

response throughout the contouring range for accurate contouring moves.

It will also allow the response to curve at speeds above the contouring

range.

Function

Use this parameter in conjunction with Acc/Dec G--codes (G47, 47.1, and

47.9) to select the type of acceleration or deceleration to use when in

positioning (G00) and exact stop modes. It does not affect the type of

acceleration or deceleration used during axis jogging or contouring or

cutting moves (G01, G02, G03).

This is not a per-axis parameter. The Acc/Dec mode selected here is

applied to all axes.

Exponential Acc/Dec -- If exponential Acc/Dec is selected for this
parameter, the axis velocity (during positioning moves) increases or

decreases at an exponential rate determined by the Programmed Delay

Constant parameter. If Exponential is selected, then Exponential

Acc/Dec will be performed during positioning, regardless of the active

Acc/Dec mode (G47.x).

10.2

Positioning ACC/DEC Mode