Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 312

Advertising
background image

Acc/Dec Parameters

Chapter 10

10-16

Figure 10.8

Exponential Acceleration Example

.20

.40

.60

.80

1.00

Time (seconds)

0

100

86

63

Feedrate

Commanded

feedrate

EXPONENTIAL

Acceleration

The following equation can be used to approximate axis speed at any time

during exponential axis deceleration:

Speed = (S

in

) - (S

in

- S

com

)(1 - e

-x

)

where :

S

in

=

Initial axis speed

S

com

=

Commanded axis speed

e

=

the natural antilogarithm

(1000/system scan time)(elapsed time in seconds)

x

=

-------------------------------------------------

(Manual Delay Constant)

As an another example, Figure 10.9 shows axis speeds at various times

during an exponential deceleration. This example assumes an initial speed

of 200 ipm, a commanded speed of 100 ipm, a system scan time of 20 ms,

and a Manual Delay Constant of 8.

Advertising