background image

Tool Offset Parameters

Chapter 22

22-25

Function

Use this parameter to specify the maximum value that a Geometry Radius

Offset may contain. This value represents the absolute maximum value per

table for all tool offsets in that table.

If the operator enters:

then:

a positive number greater than the maximum value

the control generates the error message:

a negative number less than the negative of the

maximum value

“OFFSET EXCEEDS MAX VALUE”

Refer to your programming and operation manual for more information.

Axis

Parameter Number

Single Process

Process 1

Process 2

All

[249]

[20249]

[21249]

Range

0.000000 to 390.000000 inches/9906.0000 mm

Notes

For mill and lathe applications, this parameter is global; the value set here

applies to all axes. For dual processing controls, this is a per process

parameter. The value set in the parameters applies to all of the axes

assigned to that process.

22.24

Maximum +/- Geometry

Radius

Advertising