Acc/Dec Parameters

Chapter 10

10-9

or

0.00000 to 20,000.00000 deg/sec/sec

Notes

This parameter must be set independently for each axis.

Important: If the Servo Position Loop Type parameter (chapter 7) is set

for “ZFE Closed Loop” and the Feed Forward Percentage is set relatively

high, then it is important that the axis acceleration and deceleration

ramping closely match the “natural response” of the axis.

Figure 10.4

Matching Linear Acc Ramp to the Natural Response of the Axis

Time (seconds)

Feedrate

Rapid

Linear Ramp

(slope of this line)

Natural response

curve of axis

Function

Use this parameter to select the deceleration rate for each axis during

Linear Acc/Dec Mode (G47). A 0.0 value in this parameter forces the

system to replace this value with the value set for Linear Acceleration

Ramp.

Important: If you attempt to run the axis with a high gain (refer to the

Initial Gain parameter in chapter 7), higher values are generally required

for this parameter to avoid getting the “EXCESS FOLLOWING ERROR”

message.

10.5

Linear Deceleration Ramp