Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual
Page 683
![background image](/manuals/580257/683/background.png)
Tuning AMP at the Machine
Chapter 40
40-5
3.
Press the
{HOME CALIB}
softkey.
(softkey level 4)
REVERS
ERROR
HOME
CALIB
AXIS
CALIB
SERVO
PARAM
SPNDL
PARAM
When the
{HOME CALIB}
softkey is pressed, this screen is displayed
on the operator panel CRT:
HOME CALIBRATION
AXIS
VALUE
X
0.000
[ MM ]
Y
0.000
[ MM ]
Z
0.000
[ MM ]
U
0.000
[ MM ]
REPLCE
VALUE
ADD TO
VALUE
UPDATE
& EXIT
QUIT
4.
Use the up or down cursor keys to highlight the home calibration
value that is to be changed.
For Dual Processing controls, the status bar indicates which process
is being displayed. Press the
[PROC SELECT]
key to change the
active process. You can only access the axes in the currently
selected process.
To replace the current home calibration data with new data:
press the
{REPLCE VALUE}
softkey
cursor to the position you want
key-in the new data
press
[TRANSMIT]