Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 683

Advertising
background image

Tuning AMP at the Machine

Chapter 40

40-5

3.

Press the

{HOME CALIB}

softkey.

(softkey level 4)

REVERS

ERROR

HOME

CALIB

AXIS

CALIB

SERVO

PARAM

SPNDL

PARAM

When the

{HOME CALIB}

softkey is pressed, this screen is displayed

on the operator panel CRT:

HOME CALIBRATION

AXIS

VALUE

X

0.000

[ MM ]

Y

0.000

[ MM ]

Z

0.000

[ MM ]

U

0.000

[ MM ]

REPLCE

VALUE

ADD TO

VALUE

UPDATE

& EXIT

QUIT

4.

Use the up or down cursor keys to highlight the home calibration

value that is to be changed.

For Dual Processing controls, the status bar indicates which process

is being displayed. Press the

[PROC SELECT]

key to change the

active process. You can only access the axes in the currently

selected process.

To replace the current home calibration data with new data:

press the

{REPLCE VALUE}

softkey

cursor to the position you want

key-in the new data

press

[TRANSMIT]