OCI Parameters

Chapter 38

38-8

Function

Before changing this parameter make sure you have read and understand

the watchlist concepts outlined on page 38-5.

There are four “OCI Backgrnd Buffer__Size” parameters. One for each

connecting OCI station. Use this parameter to specify the size (in bytes) of

the background watchlists for each connecting OCI station. Each OCI

station that connects to the 9/Series creates its own background and

foreground watchlists. Most data items are loaded onto the controls

background watchlist. Refer to your 9/Series OCI API developers guide

for a listing of the data items that are background and their data types.

Axis

Parameter

Number

Parameter Name

All

[336]

OCI Backgrnd Data Buffer1 Size

All

[337]

OCI Backgrnd Data Buffer2 Size

All

[338]

OCI Backgrnd Data Buffer3 Size

All

[339]

OCI Backgrnd Data Buffer4 Size

Range

50 to 10000 bytes

Notes

Important: You can assign an OCI station to a specific watchlist buffer

when the OCI stations data server is configured. The parameter

“OCIDataBuffer” in the OCIDSCFG.INI file selects the watchlist for that

OCI on any given CNC. See your 9/Series OCI installation manual for

details. If one OCI station has an application program that requires more

watchlist space than other connecting OCI stations, you can specify a

larger background watchlist number here. Than make sure the larger OCI

station always connects to this larger watchlist by assigning the

“OCIDataBuffer” parameter in the OCIDSCFG.INI file to this larger

watchlist buffer number.

This is a global parameter; the value set here applies to all axes.

END OF CHAPTER

38.4.2

OCI Backgrnd Data

Buffer__Size