Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 632

Advertising
background image

Deskew Parameters

Chapter 36

36-6

Function

This parameter selects the master servo and determines the axis name you

program when commanding the split axis. Specifying this axis name in a

part program causes the master servo selected here and the slave servo

(selected later) to move the split axis to the specified position at the

specified feedrate.

Many parameters that control axis motion and response are attained from

the values configured for the master servo. The slave servo shares the

values of these parameters with the master servo:

All Homing Parameters (except Home Calibration)
All Zones/Overtravel Parameters
All Jog Parameters including jog speeds and jog increments
All Feedrate parameters
All Acc/Dec Parameters
All Constant Surface Speed parameters
All Cutter Comp/Tool Tip Radius parameters
All Axis Program format Parameters
All Tool Offset Parameters
All Fixed Cycles parameters
All Roughing Cycle Parameters
All Cylindrical/Virtual C Parameters
the master servo(s) status in regard to the PAL controlled features,
including:

Servo Off
Servo Detach
Axis Inhibit
Axis Clamp

These are all automatically copied from the master servo to the slave

servo. PAL cannot select different states between the master and slave

servos for these features.

Any of the above parameters that have been configured for the slave servo

are ignored and replaced with the master servo’s values.

Independent AMP parameters must still be configured for the following:

All Digital Servo Parameters
All Analog Servo Parameters
All Plane Select Parameters must not contain a slave servo name

36.1

Deskew Master Servo Name

Advertising