Axis Program Format Parameters

Chapter 16

16-3

The zero suppression mode parameters are covered in the following
sections:

Parameter:

Page:

Leading Zero Suppression Mode

16-3

Trailing Zero Suppression Mode

16-4

Error if Letter Numeric Missing

16-5

Function

This parameter specifies whether leading zero suppression mode is active

when a programmed word is decoded by the control. It should be disabled

when decimal point programming is being performed. When this

parameter is enabled, the control “right-justifies” the programmed word

according to the word format of the programmed word.

Trailing zeros must be programmed to make sure that each word has its

required number of digits to the left and the right of the decimal point.

This number includes any suppressed leading zeros.

For example, if this parameter is enabled and the X-axis word format is

4.3, then X01 is decoded as X0000.001 and X2790 is decoded as

X0002.790.

Axis

Parameter

Number

All

[404]

Range

Selection

Result

(a)

Enabled

(b)

Disabled

Notes

This is a global parameter; the value set here applies to all axes and processes.

Important: Leading zero suppression mode and trailing zero suppression

mode cannot be enabled at the same time.