Power-up G-code Parameters

Chapter 19

19-18

Function

Use this parameter to select the default G-code for modal group 24. The

selected G--code specifies the type of acc/dec mode (Linear, S--Curve, or

Acc/Dec Disabled) is active.

Lathe

A

Lathe

B

Lathe

C

Mill

Control

Active Mode

G47

G47

G47

G47

Linear ACC/DEC

G47.1

G47.1

G47.1

G47.1

S--Curve ACC/DEC

G47.9

G47.9

G47.9

G47.9

ACC/DEC Disabled

Axis

Parameter Number

Single Process

Process 1

Process 2

All

[540]

[20540]

[21540]

Range

Selection

Result

(a)

G47

(Linear ACC/DEC)

(b)

G47.1 (S--Curve ACC/DEC)

(b)

G47.9 (ACC/DEC Disabled)

Notes

This is a global parameter; the value set here applies to all axes.

For dual--processing controls, this is a per process parameter. The value set

in the parameter applies to all of the axes assigned to that process.

Important: G47.9 is only programmable in AMP, not on the control via a

part program block.

END OF CHAPTER

19.17

PTO ACC/DEC Mode