Chapter

19

19-1

Power-up G-code Parameters

This chapter covers the Power-up G-code parameters. These parameters
specify which G-code is the default G-code for a specific modal G-code

group. These default G-codes become effective when the control is

powered up or when a control reset is performed. A control reset does not

change inch/metric mode from its last programmed state. The parameter

for the inch/metric PTO state (Group 6) is only applied at power up.

They may also become effective when the control executes an

end-of-program (M02 or M30) or when an E-Stop Reset is executed.

This depends on the values of AMP parameters Reset M-- and G--codes

on M02/M30 and Control Reset on E-Stop Reset found in chapter 22.

Any other G-code group not discussed here is not configurable. The

default G-code for other G-code groups is fixed and may not be changed.

The default G-codes may be displayed on the control by selecting the

{G CODE STATUS}

screen. Refer to your programming and operation

manual for more information.

Important: The operating G-code for a specific group may be altered at

any time on the control with program commands. These override the

default G-codes until one of the operations that reactivates the default

G-codes is performed.

19.0

Chapter Overview