OCI Parameters

Chapter 38

38-3

Function

Use this parameter to specify the frequency at which the control passes

updated information to the OCI station. This parameter specifies the

shortest amount of time that can pass between control updates to the OCI

station. The actual time between updates may be greater than the

minimum time configured here because of higher priority tasks being

executed by the 9/Series processor or in the event that there is no new

changed data to transmit. Data items values on the watchlist are only

transmitted when its value changes.

Selecting a longer minimum duration will reduce traffic on your network.

Selecting a shorter minimum duration will increase OCI performance for

time critical OCI applications.

Axis

Parameter

Number

All

[333]

Range

20 to 3000 milliseconds

Notes

This is a global parameter; the value set here applies to all axes.

We recommend keeping this parameter equal to or greater than the

“Monitor Frequency for Changes” parameter. Following this

recommendation will allow the system to buffer up changes and send

larger packets of data each transmit cycle improving system and network

performance.

38.2

CNC- OCI Data Transfer Rate