Using AMP Applications and ODS Utilities

Chapter 2

2-33

AMP setting -- The AMP parameter “Block Transfer Capability” when
set to enabled, also enables the pass through feature. Once downloaded

to the control, this setting remains until either AMP is lost or changed.

Softkey -- This method is discussed below. It uses a softkey to
temporarily enable block transfers and DH+ pass through. This setting

remains in effect only until the next time power is cycled or the softkey

is pressed again turning the feature off. The softkey is not available

when the AMP setting is enabled.

Use the softkey to enable DH+ pass through as follows:

1.

Press the {SYSTEM SUPORT} softkey.

(softkey level 1)

PRGRAM

MANAGE

OFFSET MACRO

PARAM

QUICK

CHECK

SYSTEM

SUPORT

2.

Press the more {Ô} softkey.

The right most softkey will be the {PT ENABLE} softkey. This key

is only visible when the AMP parameter “Block Transfer Capability”

is set to disabled and PAL has enabled remote I/O using the $RMON

flag.

3.

Press the {PT ENABLE} softkey to toggle between pass through

enabled and disable. When the softkey is shown in reverse video

block transfers and pass through is enabled. When the softkey is not

in reverse video block transfers and pass through is disabled.

(softkey level 2)

PTO

SI/OEM

SYSTEM

TIMING

SCREEN

SAVER

PT

ENABLE

Important: If you do not use block transfers and do use remote I/O single

transfers, keep in mind that when pass through is enabled the first word in

the remote I/O rack (both input and output) is not available to PAL. Refer

to the parameter “Adapter Start Module Group” for details. The warning

“CAUTION: 1ST DISCRETE RIO UNAVAIL TO PAL” is displayed

when pass through is enabled via softkey.