Miscellaneous Parameters

Chapter 37

37-21

Analyzing Your System Timing

Figure 37.1 and Figure 37.2 show the sequence in which the control scans

system tasks and updates information. The system should be run under

worst-case conditions with this parameter set to a value well above the

expected final setting. A worst-case scenario can be created by operating

the control under these conditions:

Condition

Affects the duration of these tasks in

the system foreground

your maximum number of configured axes

Servo Read, Servo Write, Axis Control

your maximum number of PAL foreground elements

PAL Foreground

your maximum number of axes in motion

Interpolation

circular or helical type of interpolation (G02,G03)
cutter compensation
probing
homing

Condition

Affects the duration of these tasks in

the system background

your maximum number of characters in the block

Part Program Decode

your maximum number of PAL background elements

PAL Background

Figure 37.1

Scan Sequence of the 9/230 and 9/260 CPU

Servo Read

PAL Foreground

Interpolation

Servo Write

Part Program Decode

PAL Background

Display Update

Low Level Diagnostics

Servo Read

Axis Control

System Scan Time (8-30 ms; AMP selectable)

System Foreground

System Background

Critical Foreground

must be greater than 2ms