Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 609

Advertising
background image

Dual Axis Parameters

Chapter 34

34-3

A warning message is generated at power up to indicate which axes have

these above features limited.

If the dual group is to be the diameter axis (selected with G07 or G08 lathe

controls only), the master axis must be configured as the diameter axis

with the parameter Diameter Axis Name discussed in chapter 4. This will

cause all axes in the dual group to be diameter axes even when decoupled.

The same logic applies to the parameter that configures the Default CSS

Axis Name discussed in chapter 13 and items such as Drilling Axis for

cycles. Assigning a dual axis member that is not the master axis of the

group to one of these parameters will have no affect on any axis in the dual

group even after that slave axis is decoupled.

When you select the “Dual Axis Parameters” group, the workstation

displays this screen:

Proj:

AMPTEST

Appl:

AMP

Util:

Edit

F2-Project F3-Application F4-Utility

F5-Configuration

F1-File

F2-Axis

F3-Options

F4-Quick Edit!

Control Type:

Mill

Axis :

X - linear

File :

TEST

- Dual Axis Parameters -

Dual Axis Group (1)

: independent axis

Dual Axis Group (1) : 1101

independent axis

(a)

group 1

(b)

group 2

(c)

group 3

(d)

group 4

(e)

group 5

(f)

If you have a dual-process control (one 9/Series executing multiple part

programs simultaneously), the Dual Axis Master -- Group x parameters

will not appear on the screen. The master axis name is determined by the

first axis AMPed in the dual axis group.