background image

Tuning a Digital or Tachless Analog System

Appendix A

A-6

This tuning procedure assumes you are using a strip chart recorder (an
oscilloscope or other device may be used however we recommend it has

either printing or storage capability for comparison of curves). Since this

is a tachless servo system you must connect the strip chart recorder to the

spindle connector and use the DAC monitor feature.

The DAC monitor feature is used to direct velocity or following error

information for a selected servo to the spindle port. The servo you are

tuning must be on the same servo card as the spindle connector used for the

strip chart recorder. 9/230 controls only have one spindle port that can be

used with all servos on that system.

ATTENTION: If a spindle (or other device) is configured and

attached to the analog out spindle port, make sure that the drive

is disabled and will be in a safe state throughout the tuning

procedure. We recommend disconnecting the wiring to this

device from the analog out spindle port when using the DAC

monitor.

Attach the strip chart recorder to the Analog Out spindle port. Refer to

your 9/Series Integration and Maintenance manual and your strip chart

recorder documentation for polarity considerations.

Turning the DAC Monitor On

The DAC monitor utility can only be enabled through a feature called

patch AMP. Patch AMP allows you to alter some AMP values from the

control without having to use the ODS AMP editor and download utilities.

The parameters to turn the DAC monitor utility on are not available to the

AMP editor in ODS.

For details on using the patch AMP feature refer to page 41-1. These patch

AMP parameters are used to configure the DAC monitor feature:

DAC Monitor Parameters

Function

# 86

#86 enables the DAC monitor on the first servo

board of 9/260 and 9/290 systems. It enables the

DAC monitor on the analog out on 9/230 systems,

and the first analog out on 9/440 controls.

# 910

Scales the DAC output for #86.

# 87

#87 enables the DAC monitor on the second servo

board of 9/260 and 9/290 systems. It enables the

DAC monitor for the second analog out on 9/440

controls.

# 930

Scales the DAC output for #87.

A.3