Servo Parameters

Chapter 7

7-25

Function

There are five different position loop algorithms that you can choose from.

Open Loop

This is used for the spindle or for any motor that the control is not to

close the position loop. Typically these motors are connected through

the ANALOG OUT connector, or TB3 on the 9/230. Some open--loop

motors can be equipped with a position feedback device which provides

the control with position information (for features such as IPR or

threading) but is not used for closed--loop motion control. The control

determines if there is a position feedback device based on your setting

of the parameter Position Loop Feedback Port. Refer to Figure 7.14 and

Figure 7.15.

Important: Spindles are always configured as “Open Loop”. The loop

type will be changed by the software during a closed--loop orient, solid

tapping operation, or any other operation that requires closed--loop

spindle operation.

Figure 7.14

Open--loop Block Diagram (no position feedback)

Analog Servo Interface

Analog Drive

Velocity

command

Amplifier

Scaling

and

ramping

Digital to

analog

converter

Velocity

comparison

Amplifier

Motor Tacho--

meter

Velocity feedback

+

--

Figure 7.15

Open--loop with Position Feedback Block Diagram

Analog Servo Interface

Analog Drive

Motor Tacho--

meter

Encoder

Velocity feedback

Position feedback

Amplifier

Amplifier

Velocity

Comparison

Scaling

and

ramping

Digital to

analog

converter

Velocity

command

Actual

position

+

--

7.2.1

Servo Position Loop Type