Acc/Dec Parameters

Chapter 10

10-15

For all practical purposes, acceleration or deceleration is completed after

five time constants. Therefore, the total acceleration or deceleration time

can be determined by multiplying the value entered here first by 20

milliseconds, and then by 5.

Axis

Parameter

Number

Axis

Parameter

Number

(1)

[1000]

(7)

[7000]

(2)

[2000]

(8)

[8000]

(3)

[3000]

(9)

[9000]

(4)

[4000]

(10)

[10000]

(5)

[5000]

(11)

[11000]

(6)

[6000]

(12)

[12000]

Range

1 to 100

Notes

This parameter must be set independently for each axis.

This equation can be used to approximate axis speed at any time during

exponential axis acceleration:

Speed = (S

in

) + (S

com

- S

in

)(1 - e

-x

)

where :

S

in

=

Initial axis speed

S

com

=

Commanded axis speed

e

=

the natural antilogarithm

(1000/system scan time)(elapsed time in seconds)

x

=

-------------------------------------------------

(Manual Delay Constant)

For example, Figure 10.8 shows axis speeds at various times during an

exponential acceleration. This example assumes an initial speed of zero, a

commanded speed of 100 ipm, a system scan time of 20 ms, and a Manual

Delay Constant of 10.

After .2 seconds (one time constant), the axis is moving at a speed of 63

ipm. After .4 seconds, the axis is moving 86 ipm.