1 jog retract velocity – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 279

Advertising
background image

Jog Parameters

Chapter 8

8-21

Function

This parameter specifies the speed at which the control moves the tool

when returning from jog retract to the position where jog retract began.

A return from jog retract is usually done when <CYCLE START> is

pressed, after performing a jog retract.

Axis

Parameter

Number

All

[330]

Range

.0060 to 243840.0000 mmpm

or

0.0002 to 9600.0000 ipm

Notes

We recommend that the jog return speed be kept relatively low so that the

control can accurately position the tool when it reaches the original

position.

This is a global parameter. The value set here applies to all axes.

8.5.1

Jog Retract Velocity

Advertising