26 maximum +/- radius offset – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual
Page 499
Advertising
![background image](/manuals/580257/499/background.png)
Tool Offset Parameters
Chapter 22
22-27
Function
Use this parameter to specify the maximum value that a Radius Offset may
contain. This value represents the absolute maximum value per table for
all tool offsets in that table.
If the operator enters:
then:
a positive number greater than the maximum value
the control generates the error message:
a negative number less than the negative of the
maximum value
“OFFSET EXCEEDS MAX VALUE”
Refer to your programming and operation manual for more information.
Axis
Parameter Number
All
[244]
Range
0.000000 to 390.000000 inches/9906.0000 mm
Notes
For grinder applications, this parameter is global; the value set here applies
to all axes.
END OF CHAPTER
22.26
Maximum +/- Radius Offset