Adaptive feed & depth parameters, 0 chapter overview, Chapter – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 587

Advertising
background image

Chapter

32

32-1

Adaptive Feed & Depth Parameters

When you select the “Adaptive Feed & Depth” group the workstation
displays this screen:

Proj:

TranLine

Appl:

AMP

Util:

Edit

F2-Project F3-Application F4-Utility

F5-Configuration

- Adaptive Feed & Depth Parameters -

Page 1 of 1

Feed Integral Torque Gain (1)

:

0.5

Feed Proportional Torque Gain (1)

:

0.1

Feedrate Acc/Dec Enable (1)

:

Disabled

Controlling Axis for Probe <P1>

:

Y

Controlling Axis Trigger Dir <P1>

:

Plus

Trigger Tolerance for Probe <P1>

:

2.540mm

Travel limit for Probe <P1>

:

254.0mm

Adaptive Depth Feedback Source <P1> :

From Probe

F1-File

F2-Axis

F3-Options

F4-Quick Edit!

F5-Process

Type : Mill

AXIS: X

<P1> - linear

P1

File :

TEST

The Adaptive Feed & Depth parameter group is only available for mill

control types. These parameters are described on these pages:

Parameter:

Page:

Feedrate Acc/Dec Enable

32-4

Feed Proportional Torque Gain

32-3

Feed Integral Torque Gain

32-2

Controlling Axis for Probe

32-9

Controlling Axis Trigger Dir

32-10

Trigger Tolerance for Probe

32-11

Travel Limit for Probe

32-12

Adaptive depth feedback source

32-13

32.0

Chapter Overview

Advertising