Adaptive feed & depth parameters, 0 chapter overview, Chapter – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual
Page 587

Chapter
32
32-1
Adaptive Feed & Depth Parameters
When you select the “Adaptive Feed & Depth” group the workstation
displays this screen:
Proj:
TranLine
Appl:
AMP
Util:
Edit
F2-Project F3-Application F4-Utility
F5-Configuration
- Adaptive Feed & Depth Parameters -
Page 1 of 1
Feed Integral Torque Gain (1)
:
0.5
Feed Proportional Torque Gain (1)
:
0.1
Feedrate Acc/Dec Enable (1)
:
Disabled
Controlling Axis for Probe <P1>
:
Y
Controlling Axis Trigger Dir <P1>
:
Plus
Trigger Tolerance for Probe <P1>
:
2.540mm
Travel limit for Probe <P1>
:
254.0mm
Adaptive Depth Feedback Source <P1> :
From Probe
F1-File
F2-Axis
F3-Options
F4-Quick Edit!
F5-Process
Type : Mill
AXIS: X
<P1> - linear
P1
File :
TEST
The Adaptive Feed & Depth parameter group is only available for mill
control types. These parameters are described on these pages:
Parameter:
Page:
Feedrate Acc/Dec Enable
32-4
Feed Proportional Torque Gain
32-3
Feed Integral Torque Gain
32-2
Controlling Axis for Probe
32-9
Controlling Axis Trigger Dir
32-10
Trigger Tolerance for Probe
32-11
Travel Limit for Probe
32-12
Adaptive depth feedback source
32-13
32.0
Chapter Overview