2 pullout angle, chamfered thrd – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 532

Advertising
background image

Fixed Cycles

Chapter 25

25-12

Function

Use this parameter for lathe controls when cutting either the single pass or

multiple pass threading cycles. The G-codes for these cycles are:

G Code System

Single Pass

Multiple Pass

A

G92

G76

B

G78

G76

C

G21

G78

This parameter determines the pullout angle “a” for the threading

chamfer feature.

If a value has been set for this and the “Pullout Distance, Chamfered

Thrd” parameters, and the PAL flag $FCPULL has been set true, then the

control automatically cuts a chamfer at the end of each threading pass

during the operation of the threading cycles. This also lets you abort a

threading pass and cut a chamfer out of the thread when the <CYCLE

STOP> button is pressed.

Refer to the lathe operation and programming manual for details on

threading chamfer.

For this parameter, enter in degrees the angle of the chamfer. The length of

the chamfer is determined by using the “Pullout Distance, Chamfered

Thread” parameter. See Figure 25.1 for examples of Pullout Distance and

Pullout Angle.

25.9.2

Pullout Angle, Chamfered

Thrd