Servo Parameters

Chapter 7

7-79

We recommend that the default value of 200% be left here if using a

standard 1326 motor paired with a 9/440 or 1394 drive (Standard Motor

Values is set to “Yes”). When using the standard motor table settings, the

9/Series will override the value you enter here and use a value appropriate

for your drive/motor combination.

Axis

Parameter

Number

Axis

Parameter

Number

(1)

[1012]

(9)

[9012]

(2)

[2012]

(10)

[10012]

(3)

[3012]

(11)

[11012]

(4)

[4012]

(12)

[12012]

(5)

[5012]

(13)

[13012]

(6)

[6012]

(14)

[14012]

(7)

[7012]

(15)

[15012]

(8)

[8012]

Range

0 to 300 %

Notes

This parameter must be set independently for each axis.

This peak torque determines the maximum force an axis can produce

during acceleration or deceleration in the negative direction.

Function

Enter the peak torque (as a percentage of rated torque) to be allowed for

attaining and maintaining position in the positive travel direction.

Since motor torque is proportional to motor current, the following equation

can be used to determine a value to be entered here:

Maximum desired motor current

-------------------------------

x 100%

Motor’s maximum rated current

Important: This parameter is only used if the velocity loop is closed in by

the CNC software.