Cutter Comp/Tool Tip Radius
Chapter 23
23-15
Function
Use this parameter when the parameter for Interference Detection is set as
enabled. If Interference Detection is enabled, it is possible to temporarily
disable interference detection by programming the M-word set with this
parameter in a block. Interference detection is disabled only for the block
that contains this M-word; any following blocks have interference
detection enabled unless they also contain this M-word.
Axis
Parameter
Number
All
[95]
Range
--1 to 999
Notes
This is a nonmodal M-word.
This parameter will not disable the interference checking feature used in
dual process systems.
This is a global parameter. The value set here applies to all axes
and processes.
23.3.3
M- word to Disable