Spindle 1 Parameters

Chapter 12

12-9

Function

This parameter specifies the number of available spindle gear ranges for a

specific machine application. The control allows for 8 spindle gear ranges.

Important: If the machine does not have multiple spindle gear ranges,

enter 1 for this parameter.

Spindle

Parameter

Number

1

[860]

Range

0 to 8

Notes

Actual spindle gear changing is implemented through PAL. When PAL

sets the gear mode request flag to “automatic,” the control uses this

parameter and the other AMP gear parameters to determine the correct

gear for the commanded spindle speed. It then requests gear changes from

PAL as needed. Refer to your PAL reference manual for more

information.

This parameter must be set for each spindle axis.

Function

It is necessary to enter the lowest and highest spindle rpm for each gear

range to optimize a machine’s performance. Overlapping ranges are

permitted. The maximum value for a specific gear must be greater than the

minimum value for that gear.

Gear change operations are controlled by the PAL program with gear

change PAL flags. Refer to your PAL reference manual for more

information.

ATTENTION: If the spindle is not capable of attaining the

speed entered for a particular gear range, program execution

may halt and/or an error message results (as determined by the

control’s PAL program).

12.5

Number of Gears Used

12.6

Minimum and Maximum

Spindle Speeds