Servo Parameters
Chapter 7
7-94
Function
Use this parameter when your servo is connected to an Allen Bradley 1394
digital drive. This parameter selects the 1394 drive axis module to which
the servo is connected. Each 1394 drive in your I/O ring can have up to
four amplifier axis modules (slots). They number from left to right, the
left most (closest to system module) being slot 0, the right most (furthest
from system module) being slot 3.
Axis
Parameter
Number
Axis
Parameter
Number
(1)
[1161]
(7)
[7161]
(2)
[2161]
(8)
[8161]
(3)
[3161]
(9)
[9161]
(4)
[4161]
(10)
[10161]
(5)
[5161]
(11)
[11161]
(6)
[6161]
(12)
[12161]
Range
0 to 3
Notes
This parameter must be set independently for each axis.
You must also identify the ring address of the 1394 drive using the
parameter ID of Amplifier Rack.
7.4.7
Amplifier Slot Number