14 scaling allowed – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 654

Advertising
background image

Miscellaneous Parameters

Chapter 37

37-14

Possible solutions include:

- alter your part program by removing or combining consecutive

nonmotion blocks that occur during cutter compensation, QPP, or

Corner/Chamfer blocks.

- reduce the Cutter Compensation Maximum Non--Motion Block

Limit in AMP (note this may change your compensation contour).

- lower the AMPed number of retrace blocks available.

- purchase more RAM.

Contact Allen-Bradley customer service for assistance on determining the

proper solution for your system.

This is a global parameter; the value set here applies to all axes. For Dual

Processing controls, this is a per process parameter. The value set with this

parameter applies to all of the axes assigned to that process.

Function

Use this parameter to specify whether scaling is allowed on a specified

axis. When this parameter is set “TRUE ” for an axis, scaling may be

applied to that axis. When this parameter is set “FALSE ” for an axis,

scaling may not be applied to that axis. Use this parameter only if the

scaling option is installed.

Refer to your programming and operation manual for more information.

Axis

Parameter

Number

Axis

Parameter

Number

(1)

[1100]

(7)

[7100]

(2)

[2100]

(8)

[8100]

(3)

[3100]

(9)

[9100]

(4)

[4100]

(10)

[10100]

(5)

[5100]

(11)

[11100]

(6)

[6100]

(12)

[12100]

Range

Selection

Result

(a)

True

(b)

False

Notes

This parameter must be set independently for each axis.

37.14

Scaling Allowed

Advertising