3 pulse count multiplier-high – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual
Page 263
Jog Parameters
Chapter 8
8-5
Function
This parameter sets the resolution of the HPG (distance the axes travels per
HPG pulse) when performing an HPG jog with <SPEED/MULTIPLY> on
the MTB panel set to MED X100.
Axis
Parameter
Number
Axis
Parameter
Number
(1)
[1357]
(7)
[7357]
(2)
[2357]
(8)
[8357]
(3)
[3357]
(9)
[9357]
(4)
[4357]
(10)
[10357]
(5)
[5357]
(11)
[11357]
(6)
[6357]
(12)
[12357]
Range
Pulse Count Multiplier- Med value to 127.00000 mm or 360.00000 degrees
or
Pulse Count Multiplier - Med value to 5.00000 inch
The minimum value that may be set for this parameter is dependant on the
value set for the parameter “Pulse Count Multiplier - Med.”
Notes
You must set this parameter independently for each axis.
The default setting for <SPEED/MULTIPLY> on the pushbutton MTB
panel is LOW X1.
8.1.3
Pulse Count Multiplier-High