Jog Parameters

Chapter 8

8-5

Function

This parameter sets the resolution of the HPG (distance the axes travels per

HPG pulse) when performing an HPG jog with <SPEED/MULTIPLY> on

the MTB panel set to MED X100.

Axis

Parameter

Number

Axis

Parameter

Number

(1)

[1357]

(7)

[7357]

(2)

[2357]

(8)

[8357]

(3)

[3357]

(9)

[9357]

(4)

[4357]

(10)

[10357]

(5)

[5357]

(11)

[11357]

(6)

[6357]

(12)

[12357]

Range

Pulse Count Multiplier- Med value to 127.00000 mm or 360.00000 degrees
or
Pulse Count Multiplier - Med value to 5.00000 inch

The minimum value that may be set for this parameter is dependant on the

value set for the parameter “Pulse Count Multiplier - Med.”

Notes

You must set this parameter independently for each axis.

The default setting for <SPEED/MULTIPLY> on the pushbutton MTB

panel is LOW X1.

8.1.3

Pulse Count Multiplier-High