7 tool offset cancel – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 481

Advertising
background image

Tool Offset Parameters

Chapter 22

22-9

Notes

This is a global parameter; the value set here applies to all axes. This

parameter does not affect the operation of the cutter compensation or the

TTRC features in any way.

Important: It is incompatible to select a geometry offset mode of “immed

shift, immed move” when the wear offset mode is configured as “immed

shift, delay move” or a geometry offset mode of “immed shift, delay

move” and a wear offset mode of “immed, shift immed move”. An error

message (INCOMPATIBLE TOOL ACTIVATION MODES) is displayed

and the control is held in E-STOP when the wear and geometry activation

mode is incompatible.

For Dual Processing controls, this is a per process parameter. The value set

in the parameters applies to all of the axes assigned to that process.

This parameter is not available for grinder applications.

Function

Use this parameter to determine what tool offsets are canceled when a

control reset is performed. These offsets can still be activated, canceled, or

replaced by the programmer at any time. You can configure your system

to perform a control reset whenever an E-STOP reset is performed using

the parameter Control Reset on E-STOP Reset (page 37-4).

Axis

Parameter Number

Single Process

Process 1

Process 2

All

[204]

[20204]

[21204]

Do Not Cancel -- When “do not cancel” is selected for this parameter, the

control does not cancel the offset values when a control reset is executed.

Cancel Wear Only -- When “cancel wear only” is selected for this

parameter, the control cancels only the wear offset when a control reset is

executed. Any geometry offset that is active is not canceled.

Cancel Geom & Wear -- When “cancel geom & wear” is selected for this

parameter, the control cancels both geometry and wear tool offset data

when a control reset is executed.

Cancel Geometry Offset -- when you select “cancel geometry offset” for

this parameter, the control cancels both length offset and radius/orientation

offset when a control reset is executed.

22.7

Tool Offset Cancel