Tool Offset Parameters

Chapter 22

22-26

Function

Use this parameter to specify the amount that a Radius Offset may change

between successive entries.

If the operator exceeds the amount set by the system installer in AMP, the

change is not allowed. The control generates the error message “OFFSET

EXCEEDS MAX CHANGE.”

Important: The control does not perform the verification if the value, old

or new, is zero, nor does it check G10 data-setting codes.

Refer to your programming and operation manual for more information.

Axis

Parameter Number

All

[245]

Range

0.000000 to 390.000000 inches/9906.0000 mm

Notes

For grinder applications, this parameter is global; the value set here applies

to all axes.

22.25

Maximum Radius Offset

Change