Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual
Page 491

Tool Offset Parameters
Chapter 22
22-19
These subsections describe the parameters used for tool offset range
verification. These parameters check:
the maximum values entering the tool offset tables
the maximum change that can occur in either table
Parameter:
Page:
Maximum Wear Offset Change
22-19
Maximum Geometry Offset Change
22-20
Maximum +/-- Wear Offset
22-22
Maximum +/-- Geometry Offset
22-23
Maximum +/-- Wear Radius
22-24
Maximum +/-- Geometry Radius
22-25
Maximum Radius Offset Change
22-26
Maximum +/-- Radius Offset
22-27
Function
Use this parameter to specify the amount that a Wear Offset may change
between successive entries.
If the operator exceeds the amount set by the system installer in AMP, the
change is not allowed. The control generates the error message “OFFSET
EXCEEDS MAX CHANGE.”
Important: The control does not perform the verification if the value, old
or new, is zero, nor does it check G10 data-setting codes.
Refer to your programming and operation manual for more information.
22.18
Tool Offset Range
Verification Parameters
22.19
Maximum Wear Offset
Change