Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 491

Advertising
background image

Tool Offset Parameters

Chapter 22

22-19

These subsections describe the parameters used for tool offset range
verification. These parameters check:

the maximum values entering the tool offset tables

the maximum change that can occur in either table

Parameter:

Page:

Maximum Wear Offset Change

22-19

Maximum Geometry Offset Change

22-20

Maximum +/-- Wear Offset

22-22

Maximum +/-- Geometry Offset

22-23

Maximum +/-- Wear Radius

22-24

Maximum +/-- Geometry Radius

22-25

Maximum Radius Offset Change

22-26

Maximum +/-- Radius Offset

22-27

Function

Use this parameter to specify the amount that a Wear Offset may change

between successive entries.

If the operator exceeds the amount set by the system installer in AMP, the

change is not allowed. The control generates the error message “OFFSET

EXCEEDS MAX CHANGE.”

Important: The control does not perform the verification if the value, old

or new, is zero, nor does it check G10 data-setting codes.

Refer to your programming and operation manual for more information.

22.18

Tool Offset Range

Verification Parameters

22.19

Maximum Wear Offset

Change

Advertising