Home Parameters

Chapter 5

5-14

Function

This parameter specifies the feedrate at which the axis moves to come off

the home limit switch.

This feedrate is used for manual and automatic homing. It is used in

coming off the switch and also in moving to the calculated home position.

When a homing operation is being executed, this feedrate cannot be altered

by any feedrate overrides.

Axis

Parameter

Number

Axis

Parameter

Number

(1)

[1350]

(7)

[7350]

(2)

[2350]

(8)

[8350]

(3)

[3350]

(9)

[9350]

(4)

[4350]

(10)

[10350]

(5)

[5350]

(11)

[11350]

(6)

[6350]

(12)

[12350]

Range

0.0060 to 10160.0000 mmpm

or

0.0002 to 400.0000 ipm

Notes

This parameter is not used for systems that use distance coded marker

linear feedback devices.

This parameter must be set independently for each axis.

5.1.6

Home Speed from Limit