Zone/Overtravel Parameters
Chapter 6
6-12
Function
Use this parameter to enter the smaller machine coordinate value that
determines the location of programmable zone 3. This value may be
altered on the control, if desired, by using the programmable zone table or
by the proper programming commands. The area defined as
programmable zone 3 limits axis motion according to the position of the
axis when the zone is activated.
Axis
Parameter
Number
Axis
Parameter
Number
(1)
[1008]
(7)
[7008]
(2)
[2008]
(8)
[8008]
(3)
[3008]
(9)
[9008]
(4)
[4008]
(10)
[10008]
(5)
[5008]
(11)
[11008]
(6)
[6008]
(12)
[12008]
Range
--999999.99000 mm to Limit 3 max value
or
--39370.07835 inch to Limit 3 max value
The range of this parameter is dependent on the value set for the parameter
“Limit 3 Max value.”
Notes
This parameter must be set independently for each axis.
6.1.6
Limit 3 Min Value