6 limit 3 min value – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 138

Advertising
background image

Zone/Overtravel Parameters

Chapter 6

6-12

Function

Use this parameter to enter the smaller machine coordinate value that

determines the location of programmable zone 3. This value may be

altered on the control, if desired, by using the programmable zone table or

by the proper programming commands. The area defined as

programmable zone 3 limits axis motion according to the position of the

axis when the zone is activated.

Axis

Parameter

Number

Axis

Parameter

Number

(1)

[1008]

(7)

[7008]

(2)

[2008]

(8)

[8008]

(3)

[3008]

(9)

[9008]

(4)

[4008]

(10)

[10008]

(5)

[5008]

(11)

[11008]

(6)

[6008]

(12)

[12008]

Range

--999999.99000 mm to Limit 3 max value

or

--39370.07835 inch to Limit 3 max value

The range of this parameter is dependent on the value set for the parameter

“Limit 3 Max value.”

Notes

This parameter must be set independently for each axis.

6.1.6

Limit 3 Min Value

Advertising