Home Parameters

Chapter 5

5-6

Figure 5.1

Typical Homing Sequence

Encoder marker

Home limit switch

(1) (2)

(3) (4)

Off

On

(5)

(6)

(9)

(8)

(7)

HOME

CALIBRATION

distance

Distance

to nearest

marker

Though not yet homed, the control picks up the encoder

marker and records feedback counts since last marker

Initial move to find home switch

1/8

1/8

Home tolerance exceeded area

Single Turn Absolute Encoder Considerations

In controls that incorporate single turn absolute encoders (8500 series

digital servo motors), the absolute single turns register of these encoders

must be reset to zero after the initial manual homing sequence has taken

place. The single turn absolute encoders should not have to be reset again

unless the encoder’s battery backup fails. The zero position of each

encoder will then be assigned the coordinate value entered for the Axis

Position after Homing parameter of each axis.