4 maximum interference check zones – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 145

Advertising
background image

Zone/Overtravel Parameters

Chapter 6

6-19

Function

Use this parameter to specify the number of interference checking zones

available. The number of zones available should be equal to the number of

tool stations available on the machine.

Axis

Parameter Number

Process 1

Process 2

All

[20223]

[21223]

Range

1 to 32

Notes

This is a per process parameter. The value set here applies to all axes

assigned to that process.

END OF CHAPTER

6.3.4

Maximum Interference

Check Zones